- Field assembled insulating flange shall be tested with 1500VDC applied across the flange for 1 minute without causing break down or flash over.
- Electrical test to verify the insulating of the joint/ flange assembly for minimum of 1 MΩ for new flange.
- Electrical insulation of in service insulating joints can be measured by Swain Clamp On Ammeter.
- Electrical insulation of in service insulating joints can be tested by remote reference potential methods, if the potential difference is greater than 10 mV, then the insulation is sound.
- Point to point voltage measurement: if the potential difference is greater than 10 mV, then the insulation is sound.
- Magnetic compass method may be utilised for shorting of the insulating joints.
- Radio Frequency (RF) tester shall give reliable dielectric testing results, e.g. Tinker & Rasor RF-IT Note: proper types to be used.
- Capacitance Effect tester used for dielectric testing for underground isolator, e.g. Tinker& Rasor CE-IT.
- No Ohm meter method should be accepted as dielectric testing for insulating flange joint in service.
- High voltage insulation tester such as Megger tester shall NOT be used for in service environment.
- Welding should be carried out with the short connection of insulating joints, the jumper cable should be removed as long as welding is completed.
Can you please clarify why the Megger tester is not recommended?
Also , is there a difference between testing with the line in service and not in service.? If any, can you please clarify why.
Thanks
Thank you for this information, but I have a question. Which IEC guideline or whatever guideline says anything about this testing?
I am looking for a guideline.